Carbolite - Technical Guide
FEATURES SIZE MM CLEAR GREY  SOLAR ICE

SOLAR METAL 

BRONZE

Light Transmittance

8

86%

42%

20%

25% 

42%

10

86%

42%

20%

25%

 42%

Shading Coefficient Mean Average *

All

72%

45%

25%

28% 

45%

Solar Heat Gain Mean Average**

All

590

372

363

389 

416

Thermal Expansion

All

2.5mm

4.0m

2.5mm

2.5mm 

4.0mm

U-Factor °C***

8

3.4

3.4

3.4

3.4 

3.4

10

3.2

3.2

3.2

3.2

 3.2

Minimum Radius for Arches in metres

8

1400mm

1400mm

1400mm

1400mm 

1400mm

10

1750mm

1750mm

1750mm

1750mm

 1750mm

Weight Kg per Metre2

8

1.5/1.7

1.5/1.7

1.5/1.7

1.5/1.7 

1.5/1.7

10

2.0

2.0

2.0

2.0

2.0 
Sheet Lengths in metres 8 1.5m then increments of 500mm up to 7.2m
10 1.5m then increments of 50mm up to 7.2m
Sheet Widths 8 700 ,1050,1220mm
10 980,1050mm

RAFTER CENTRES for 8mm sheets                                                                                 RAFTER CENTRES for 10mm sheets

700mm                           Centres are 725mm                                                                  700mm                        Centres are 715mm

1050mm                         Centres are 1075mm                                                               1050mm                      Centres are 1065mm

1220mm                         Centres are 1245mm

Notes:

* Shading Co-efficient: The ratio of solar heat gain through Carbolite sheet to the solar heat gain of clear glass in a specific set of conditions.

** Solar Heat Gain: The amount of heat in W/m2 transmitted through the Carbolite sheets. Results are determined by the incidence of solar radiation.

*** U-Factor: The rate of heat transferred through the Carbolite sheet in W/m2  °C. The overall heat transfer co-efficient.

Fire Ratings: AS1530.3 1999

Carbolite sheets have been tested in accordance with Australian Standard 1530.3/1999. The test standard is for the early fire hazard properties of materials and covers four categories.

1. Ignitability
Test Index 0-10
2. Spread of Flame
Test Index 0-10
3. Heat Involved
Test Index 0-10
Smoke Developed
Test Index 0-10
Carbolite RESULTS 0 0 0 2
 
 
TEST COMPLIANCES FOR CARBOLITE SHEET
 
Design and Installation                  AS/NZS 1562.3:1996
Early Fire Hazard Test                 AS/NZS  1530.3:1999
Heat and Smoke Release             AS/NZS  3837:1998
Sandbag Impact Test                   AS/NZS  4040.4:1996
99.9% UV Resistant                    ISO 950:2003
SAA Loading Code                     AS/NZS 1170.2:2002
Part 2 WInd Loads
Resistant to pressures
Non- Cyclonic Regions               AS 4040.2:1992

200 Times Stronger Than Glass